# modbus
Modbus library with TCP Master & Slave implementation.
For Serial RTU see [baud](https://github.com/samuelventura/baud).
Based on:
- http://modbus.org/docs/PI_MBUS_300.pdf
- http://modbus.org/docs/Modbus_Messaging_Implementation_Guide_V1_0b.pdf
- http://modbus.org/docs/Modbus_over_serial_line_V1_02.pdf
## Installation and Usage
1. Add `modbus` to your list of dependencies in `mix.exs`:
```elixir
def deps do
[{:modbus, "~> 0.3.9"}]
end
```
2. Use as TCP master:
```elixir
# run with: mix opto22
alias Modbus.Tcp.Master
# opto22 learning center configured with script/opto22.otg
# the otg is for an R2 but seems to work for R1, EB1, and EB2
# digital points increment address by 4 per module and by 1 per point
# analog points increment address by 8 per module and by 2 per point
{:ok, pid} = Master.start_link(ip: {10, 77, 0, 10}, port: 502)
# turn on 'alarm'
:ok = Master.exec(pid, {:fc, 1, 4, 1})
# turn on 'outside light'
:ok = Master.exec(pid, {:fc, 1, 5, 1})
# turn on 'inside light'
:ok = Master.exec(pid, {:fc, 1, 6, 1})
# turn on 'freezer door status'
:ok = Master.exec(pid, {:fc, 1, 7, 1})
:timer.sleep(400)
# turn off all digital outputs
:ok = Master.exec(pid, {:fc, 1, 4, [0, 0, 0, 0]})
# read the 'emergency' switch
{:ok, [0]} = Master.exec(pid, {:rc, 1, 8, 1})
# read the 'fuel level' knob (0 to 10,000)
{:ok, data} = Master.exec(pid, {:rir, 1, 32, 2})
[_] = Modbus.IEEE754.from_2n_regs(data, :be)
# write to the 'fuel display' (0 to 10,000)
data = Modbus.IEEE754.to_2_regs(+5000.0, :be)
:ok = Master.exec(pid, {:phr, 1, 16, data})
```
3. Play with TCP slave:
```elixir
# run with: mix slave
alias Modbus.Tcp.Slave
alias Modbus.Tcp.Master
# start your slave with a shared model
model = %{0x50 => %{{:c, 0x5152} => 0}}
{:ok, spid} = Slave.start_link(model: model)
# get the assigned tcp port
port = Slave.port(spid)
# interact with it through the master
{:ok, mpid} = Master.start_link(ip: {127, 0, 0, 1}, port: port)
{:ok, [0]} = Master.exec(mpid, {:rc, 0x50, 0x5152, 1})
...
```
## Endianess
- [Erlang default endianess is BIG](http://erlang.org/doc/programming_examples/bit_syntax.html#Defaults)
- [MODBUS default endianess is BIG (p.34)](http://modbus.org/docs/PI_MBUS_300.pdf)
- [MODBUS CRC endianess is LITTLE (p.16)](http://modbus.org/docs/PI_MBUS_300.pdf)
- [Opto22 FLOAT endianess is BIG (p.27)](http://www.opto22.com/documents/1678_Modbus_TCP_Protocol_Guide.pdf)
## Roadmap
Future
- [ ] Improve documentation and samples
- [ ] Improve error handling
Version 0.3.8
- [x] Shared and slave for testing purposes only
- [x] Removed client (no clear api)
Version 0.3.7
- [x] Changed little endian flag from :se to :le
Version 0.3.6
- [x] Added endianness flag to float helpers
Version 0.3.5
- [x] Added float helper
Version 0.3.4
- [x] Fixed RTU CRC endianess
Version 0.3.3
- [x] Shared model slave implementation
Version 0.3.2
- [x] Added request length prediction
- [x] Refactored namespaces to avoid baud clash
- [x] Tcp master api updated to match baud rtu master api
Version 0.3.1
- [x] Added master/slave test for each code
- [x] Added response length prediction
- [x] Added a couple of helpers to tcp and rtu api
- [x] A reference-only tcp slave added in test helper
Version 0.3.0
- [x] Modbus TCP slave: wont fix, to be implemented as forward plugin
- [x] API breaking changes
Version 0.2.0
- [x] Updated documentation
- [x] Renamed commands to match spec wording
Version 0.1.0
- [x] Modbus TCP master
- [x] Request/response packet builder and parser
- [x] Device model to emulate slave interaction